◆ Unique and nasal tube respiration measurement. Accurate respiration rate and wave only can be achieved by nasal tube respiration when patient can not repose completely.
◆ Streamline outward appearance design, High-lightness LED digital tube display
◆ Easy operation with rotated mouse
◆ Low power design, rechargeable high-energy built-in battery.
◆ Fast and accurate measurement of blood pressure, a function of venous-puncture
◆ Using advance Analog technology, accurately measure the Spo2 in low perfusion situation.
◆ Audible & visual alarm available and alarm limits are adjustable.
◆ Suitable for adults, pediatrics, neonates.
◆ Application in hospital like emergency pre-and post-operative care, theater\operating room, intermediate care\step down units, labor and delivery, hospital-based special procedure areas and outdoor ambulance surgery.
◆ Communication functions to network with central monitoring system.Long-distance monitoring and software upgrade
◆ Unique and nasal tube respiration measurement. Accurate respiration rate and wave only can be achieved by nasal tube respiration when patient can not repose completely.
◆ Streamline outward appearance design, High-lightness LED digital tube display
◆ Easy operation with rotated mouse
◆ Low power design, rechargeable high-energy built-in battery.
◆ Fast and accurate measurement of blood pressure, a function of venous-puncture
◆ Using advance Analog technology, accurately measure the Spo2 in low perfusion situation.
◆ Audible & visual alarm available and alarm limits are adjustable.
◆ Suitable for adults, pediatrics, neonates.
◆ Application in hospital like emergency pre-and post-operative care, theater\operating room, intermediate care\step down units, labor and delivery, hospital-based special procedure areas and outdoor ambulance surgery.
◆ Communication functions to network with central monitoring system.Long-distance monitoring and software upgrade
Specification
NIBP
Test principle Automatic oscillometric
Patients types Adult、pediatric、and neonate
Measurement parameters, systolic mean, diastolic
Measurement type Manual、automatic、and continuous
Measurement rang 15-300mmHg
Units of measurement mmHg/kPa optional
Accuracy ±2 mmHg
Respiration
Measurement range:0 BPM- 120 BPM
Accuracy :±1 BPM or ±5 %
Body temperature
Measurement range 20.0~45.0℃
Display T1、T2
Units of measurement: ℃/℉ optional
Accuracy ±0.1℃
Spo2
Measurement range 0-100% Resolution 1%
Pulse rate range 30-250 BPM
Accuracy ±2%
Standard parameter: Respiration+ Temperature+NIBP+Spo2(Built in rechargeable battery)
Environmental Specifications
Operation
Temperature:5 to 45℃
Relative humidity: ≤ 80 %
Air pressure:70 to 106 kPa
Transport and Storage:
Temperature:-20 to 55℃
Relative humidity ≤ 93%
Air Pressure:50 to 106 kPa
Input voltage:100 to 240 V
Frequency:50/60 Hz
Power:80VA
Operation time:≥ 8 hours
Internal battery:≥ 1 hour
Connectors of signs
CRT: Standard VGA connectors
NET: RJ45 connectors