Contact Us

(+966) 012 420 91 20

g3s-%e6%ad%a3%e9%9d%a2

 

 

 

 

 

 

Product Description

◆ Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be

influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.

◆ Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal

tube respiration can detect the right respiration waveform and respiration rate).

◆ 12.1’’ color TFT LCD screen, High brightness, Wide viewing, 8 waveforms can be displayed on the same screen . lightness

and volume are adjustable independently.

◆ Streamlined outline design with sense of the times & foldable handle.

◆ Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian,

Turkish, etc.

◆ User-friendly and man-machine dialogue interface with pop-up menus, dialogue boxes, rotary mouse and etc.

◆ Low-power consumption design with standby mode, rechargeable high-energy built-in battery.

◆ blood pressure measurement fast and accuratly, with venipuncture function.

◆ Advanced digital technology, accurately measure SpO2 in low perfusion situation.

◆ Drug calculation, ST-segment detection, pace maker and arrhythmia analysis.

◆ display format include OxyCRG diagram, 7-lead ECG waveform, big-font mode simultaneously ; can store 5 kinds of

user-defined display format;

◆ Sound and light integrated alarm, Alarm parameters can be adjusted to upper or lower.

◆ Suitable for adults, pediatrics and neonates

◆ Applications in bedside and delivery monitoring; Widely used in patient room, emergency room, operation room, PACU,

ICU, CCU, etc.

◆ WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis,

maintenance and software upgrade possible.

◆ Printing of data, waveform, trend tables and trend diagram.

◆ Optional CO2 detection function

Specifications

ECG

Heart rate(HR)

Measurement range: 30BPM ~ 350BPM;

Accuracy: 1 BPM or ±1 %.

Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance :

± 10%

Noise level: ≤ 30μV

ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current:

≤ 0.1μAECG sensitivity: continuous adjustable

The scanning speed of the sub-file and error:

Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%

 

 

NIBP

Measurement range:

Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg

Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg

Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg

Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%

 

 

IBP

Measurement range: -1.3~40KPa(-10 ~ 300mmHg)

Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg

Unit display: kPa or mmHg( selectable)

Respiration Rate

Measurement range: 0 BPM ~ 120 BPM;

Accuracy: ±1 BPM or ±5 %

 

Temperature

Number of channels: 2

Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit

Measurement range: 25.0 ℃~ 45.0℃

Accuracy: ± 0.2 ℃

Response time: ≤ 3 min.

 

GMI SpO2   

Display type: Waveform, data

Measurement range: 0~100%

Resolution: 1 BPM

Pulse rate range: 30~250bpm

Accuracy: ±1bpm

 

Pulse Rate

Measurement range: (30 ~ 250)bpm;

Accuracy: 1BPM or ±2%

Trend review:

Can Review history data of 360 hours

 

CO2

Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation)

Accuracy: ±2mmHg(<5﹪ Measured values)

10﹪(>5﹪ Measured values)

 

Standard configuration ECG, NIBP,  SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery.
Optional configuration Built-in printer, GMI SpO2, Nellcor SpO2,2-IBP, ETCO2(main stream or side

 

Environment

Temperature: (+5 ~ +45)℃;

Operation & Storage: (-20 ~ +55)℃

Relative humidity : ≤ 80 %

Operation & Storage:≤ 93 %

Atmospheric pressure: (700 ~ 1060)hPa

Operation & Storage:(500 ~ 1060)hPa

Adapt to power: (100 ~ 240)V a.c. 50/60Hz,

Maximum input power: 80VA

Fuse: T 1.6 A

Continuous working time:

Network power working time : ≥ 8 hours

Internal power continuous working: > 1 hour (In premise of full battery, and measuring blood pressure every 10 minutes)

Signal Interface:( External monitor): standard VGA port (optional)

PRINTER(External printer): PC/AT Parallel Interface

NET (External central monitor): RJ45 port

LINE(External telephone line): MODEM port