Contact Us

(+966) 012 420 91 20


Warning: preg_match(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 1384

Warning: preg_match_all(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 700

Warning: Invalid argument supplied for foreach() in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 707

Warning: preg_match_all(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 700

Warning: Invalid argument supplied for foreach() in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 707

G3L Multi-parameter patient monitor

 

Product Description

Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.

Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal tube respiration can detect the right respiration waveform and respiration rate).

15’’ color TFT LCD screen, High brightness,Wide viewing, 12 waveforms can be displayed on the same screen . lightness and volume are adjustable independently.

Streamlined outline design with sense of the times & foldable handle. Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.

Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.

Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal tube respiration can detect the right respiration waveform and respiration rate).

User-friendly and man-machine dialogue interface with pop-up menus, dialogue boxes, rotary mouse and etc.

Low-power consumption design with standby mode, rechargeable high-energy built-in battery.

blood pressure measurement fast and accuratly, with venipuncture function.

Advanced digital technology, accurately measure SpO2 in low perfusion situation.

Drug calculation, ST-segment detection

display format include OxyCRG diagram, 7-lead ECG waveform, big-font mode simultaneously ; can store 5 kinds of user-defined display format;

Sound and light integrated alarm, Alarm parameters can be adjusted to upper or lower.

Applications in bedside and delivery monitoring; Widely used in patient room, emergency room, operation room, PACU, ICU, CCU, etc.

WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.

Specifications

Lead output: 3 wires/5 wires ECG cable

Lead section: I, II, III, aVR, aVL, aVF, V

Gain selection: ×1/4, ×1/2, ×1, ×2, ×4 and automatic

Scan speed: 6.25 mm/s 、12.5 mm/s 、25 mm/s、50mm/s

Heart rate range: 15-300bpm

ECG calibration: ± 1 mvHeart rate accuracy: ± 1%

 

NIBP

Philosophy: Oscillometric method

Measurement type: adult, pediatric, neonate

Measurement parameter: Systolic, Diastolic, Mean

Measurement method: manual, automatic, continuous measurement

Unit: mmHg/kPa selectable

Accuracy: ±2 or 3mmHg

 

SpO2

Display type: Waveform, data

Measurement range: 0~100%

Resolution: 1 BPM

Pulse rate range: 30~250bpm

Accuracy: ±1bpm

Temperature

Number of channel: 2 channels, measure surface and cavity temperature simultaneously

Resolution: 0.1℃

Display: T1, T2, △T

 

Respiration

Thoracic impedance & nasal tube double method selectable

Measurement range: 0~120bpm

Accuracy: ±1bpm

Resolution: 1bpm

 

ETCO2 (Option)

Measuring Method: main/side stream typeMeasurement range: 0%-10.0%

Accuracy: ±2mmHg

 

2-IBP (Invasive blood pressure) (Option)

Measurement range: -10-300mmHgChannel: max 4 channels

Accuracy:±1mmHg or ±2%Transducer sensitivity: 5uV/V/mmHg

Pressure label: ART、CVP、RVP、LAP、RAP、PAP、ICP、LVP

 

Cardiac Output (Option)

Measuring Method: thermodilution

Blood temperature measurement and alarm range: 23 ℃~ 43℃

Unit: degrees Celsius ℃ or Fahrenheit ℉

Error: ±0.2 ℃

Resolution: 0.1℃

Cardiac output measurement range: 0.1L/min ~ 20.0 L/min

Error: ±0.2 L/min or ±5%

Power requirement: 100~240VAC, 50/60Hz