Contact Us

(+966) 012 420 91 20


Warning: preg_match(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 1384

Warning: preg_match_all(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 700

Warning: Invalid argument supplied for foreach() in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 707

Warning: preg_match_all(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 700

Warning: Invalid argument supplied for foreach() in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 707

G2A Vital Signs Monitor
Product Description
◆ Unique and nasal tube respiration measurement. Accurate respiration rate and wave only can be achieved by nasal tube respiration when patient can not repose completely.

◆ Streamline outward appearance design, High-lightness LED digital tube display

◆ Easy operation with rotated mouse

◆ Low power design, rechargeable high-energy built-in battery.

◆ Fast and accurate measurement of blood pressure, a function of venous-puncture

◆ Using advance Analog technology, accurately measure the Spo2 in low perfusion situation.

◆ Audible & visual alarm available and alarm limits are adjustable.

◆ Suitable for adults, pediatrics, neonates.

◆ Application in hospital like emergency pre-and post-operative care, theater\operating room, intermediate care\step down units, labor and delivery, hospital-based special procedure areas and outdoor ambulance surgery.

◆ Communication functions to network with central monitoring system.Long-distance monitoring and software upgrade

Specification

NIBP

Test principle Automatic oscillometric

Patients types Adult、pediatric、and neonate

Measurement parameters, systolic mean, diastolic

Measurement type Manual、automatic、and continuous

Measurement rang 15-300mmHg

Units of measurement mmHg/kPa optional

Accuracy ±2 mmHg

Respiration

Measurement range:0 BPM- 120 BPM

Accuracy :±1 BPM or ±5 %

Body temperature

Measurement range 20.0~45.0℃

Display T1、T2

Units of measurement: ℃/℉ optional

Accuracy ±0.1℃

Spo2

Measurement range 0-100% Resolution 1%

Pulse rate range 30-250 BPM

Accuracy ±2%

Standard parameter: Respiration+ Temperature+NIBP+Spo2(Built in rechargeable battery)

Environmental Specifications

Operation

Temperature:5 to 45℃

Relative humidity: ≤ 80 %

Air pressure:70 to 106 kPa

 

Transport and Storage:

Temperature:-20 to 55℃

Relative humidity ≤ 93%

Air Pressure:50 to 106 kPa

Input voltage:100 to 240 V

Frequency:50/60 Hz

Power:80VA

Operation time:≥ 8 hours

Internal battery:≥ 1 hour

 

Connectors of signs

CRT: Standard VGA connectors

NET: RJ45 connectors