Products ☞ measuring devices ☞ G2A Vital Signs Monitor


Warning: preg_match(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 1384

Warning: preg_match_all(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 700

Warning: Invalid argument supplied for foreach() in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 707

Warning: preg_match_all(): Compilation failed: invalid range in character class at offset 4 in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 700

Warning: Invalid argument supplied for foreach() in /home/customer/www/najah.sa/public_html/wp-content/plugins/lightbox-plus/classes/shd.class.php on line 707

G2A Vital Signs Monitor

Main Feature
1. Unique and nasal tube respiration measurement. Accurate respiration rate and wave only can be
achieved by nasal tube respiration when patient can not repose completely.
2.Streamline outward appearance design, High-lightness LED digital tube display
3.Easy operation with rotated mouse
4.Low power design, rechargeable high-energy built-in battery.
5.Fast and accurate measurement of blood pressure, a function of venous-puncture
6.Using advance Analog technology, accurately measure the Spo2 in low perfusion situation.
7.Audible & visual alarm available and alarm limits are adjustable.
8.Suitable for adults, pediatrics, neonates.

Product Description

◆ Unique and nasal tube respiration measurement. Accurate respiration rate and wave only can be achieved by nasal tube respiration when patient can not repose completely.

◆ Streamline outward appearance design, High-lightness LED digital tube display

◆ Easy operation with rotated mouse

◆ Low power design, rechargeable high-energy built-in battery.

◆ Fast and accurate measurement of blood pressure, a function of venous-puncture

◆ Using advance Analog technology, accurately measure the Spo2 in low perfusion situation.

◆ Audible & visual alarm available and alarm limits are adjustable.

◆ Suitable for adults, pediatrics, neonates.

◆ Application in hospital like emergency pre-and post-operative care, theater\operating room, intermediate care\step down units, labor and delivery, hospital-based special procedure areas and outdoor ambulance surgery.

◆ Communication functions to network with central monitoring system.Long-distance monitoring and software upgrade

Specification

NIBP

Test principle Automatic oscillometric

Patients types Adult、pediatric、and neonate

Measurement parameters, systolic mean, diastolic

Measurement type Manual、automatic、and continuous

Measurement rang 15-300mmHg

Units of measurement mmHg/kPa optional

Accuracy ±2 mmHg

Respiration

Measurement range:0 BPM- 120 BPM

Accuracy :±1 BPM or ±5 %

Body temperature

Measurement range 20.0~45.0℃

Display T1、T2

Units of measurement: ℃/℉ optional

Accuracy ±0.1℃

Spo2

Measurement range 0-100% Resolution 1%

Pulse rate range 30-250 BPM

Accuracy ±2%

Standard parameter: Respiration+ Temperature+NIBP+Spo2(Built in rechargeable battery)

Usage

Environmental Specifications

Operation

Temperature:5 to 45℃

Relative humidity: ≤ 80 %

Air pressure:70 to 106 kPa

 

Transport and Storage:

Temperature:-20 to 55℃

Relative humidity ≤ 93%

Air Pressure:50 to 106 kPa

Input voltage:100 to 240 V

Frequency:50/60 Hz

Power:80VA

Operation time:≥ 8 hours

Internal battery:≥ 1 hour

 

Connectors of signs

CRT: Standard VGA connectors